Medium-pressure regulator type 112
Application and specifications
Application
Reduces the inlet gas pressure and automatically maintains the specified outlet pressure. The required version is selected according to the process medium, flow rate, and inlet and outlet pressure ranges.
Installation and operation
The regulator must operate on clean gas. A strainer is installed upstream of the regulator. Installation is horizontal; the standard flow direction is right to left.
- Working / inlet pressure
- p1 = max 19 bar (KGF/CM²)
- Outlet pressure
- p2 = 0,2 ÷ 10 bar (KGF/CM²)
- DN / size
- G1/4" - G3/4" PN25
- Temperature
- U and KhL (down to - 60 °C)
Materials
| Body | AlSi |
|---|---|
| Seat | CW614N (CuZn40) |
| Seat plug | CW614N (CuZn40) |
| Spring / setting spring | carbon spring steel |
| Adjusting screw | CW614N (CuZn40) |
| Diaphragms 7a / 7b | Effbe |
| Cap | plastic |
Dimensions and accuracy class
| G1 | G 1/4″ or G 1/2″ |
|---|---|
| G2 | G 1/4″, G 1/2″ or G 3/4″ |
| A / B / C | 100 / 363 / 189 mm |
| p₂ range | 1-10 bar |
| RG / ZG | 5 / 10 |
Documentation and technical sheets
Open the technical data sheet and drawings at full size or download the PDF.
We will select Type 112 to match your system parameters
Provide the process medium, pressure, flow rate, temperature and connection — our specialists will check whether the version is applicable.
- We will verify compliance with the working parameters
- We will confirm the climatic and material version
- We will prepare a proposal and documentation